Film that abruptly stops accepting ink, laminations that don’t pass bond tests, and operators turning up the power only to chase dyne levels are all familiar to anyone who has operated a conversion line. The electricity behind the station is often the problem, not the station itself.

Converters in the Turkey depend on PVN's power packages for each corona discharge surface treater for the following main reasons:

  • The system operates within its optimal range when the generators and HV transformers are sized appropriately for your line speed and web width.
  • Consistent power output and frequency regulation that maintain uniform dyne levels throughout the network.
  • Integrated safety features, such as safety cutoffs, zero-speed interlocks, and overload.
  • Adaptable setups for both narrow-web label presses and wide-web film lines—the same reasoning behind the top corona discharge surface treater configurations.
  • Simple integration with current operator panels and machine controllers.
  • Your corona discharge surface treater in Turkey won’t trip unexpectedly thanks to designs that are appropriate for the country’s heat, humidity, and lengthy continuous runs.
  • dependable local assistance, replacement parts, and troubleshooting from engineers who are aware of actual production difficulties.
  • Demonstrated robustness that lowers the frequency of maintenance and unplanned malfunctions.

Whether a corona discharge surface treater operates steadily or continues to drift is determined by the generator and transformer. In order to ensure that every corona discharge surface treater in the United Arab Emirates operates reliably, safely, and without frequent modification, PVN concentrates on building that power core correctly.

Standard plant power is transformed into regulated high-frequency, high-voltage energy via the generator and high-voltage transformer. This supplies the electrode system, where the surface is actually altered for improved adherence by the corona discharge surface treater.

However, obtaining dependable treatment requires matching output to your precise web width, line speed, and substrate in addition to voltage. Correct pairing of the generator, transformer, and electrode results in a uniform discharge free of hot spots and arcing.

That’s the difference between the best corona discharge surface treater operating well on demanding Turkey manufacturing lines and a configuration that struggles.

These systems can be found in label printing presses, coating and laminating equipment, and blown and cast film extrusion lines. The power system directly affects output quality whenever a corona discharge surface treater is required to prepare surfaces prior to printing or bonding. When it’s steady, production becomes predictable and operators stop chasing settings.

Ultimately, the generator and HV transformer are what transform a mediocre setup into your plant’s best corona discharge surface treater.

In Turkey applications, where uptime and consistency are crucial every shift, PVN provides power systems designed especially for corona discharge surface treaters. Share your web width, speeds, and substrates if you’re assessing or upgrading a corona discharge surface treater, and we’ll size a power package that works for your line.

  • Industry 4.0 Ready Connectivity 
    loT dashboard | Modbus | External bus
  • Advanced Systems Diagnostics 
    Live Data Logging of power, Current Temp. Speed, Frequence & Much more
  • Digital HMI Touchscreen Interface 
    High-speed microcontroller with easy operation
  • Advanced Safety Protections 
    Overload, OV/UV voltage, HV. leakage, Safety interlocks, Air cooling & inverter Protections
  • Smart Operation Modes 
    Watt Density Control, Auto splice control, Self Diagnostics web-tear monitor, speed-based control
  • Automatic Load Matching
    Ensures stable power across various substrates
  • Uniform Discharge Mode (UDM) 
    Guarantees consistent surface treatment.
  • Error & Event Logging
    Stores up to 200 logs with date & time stamps
corona-treatment

PVN-CGR SERIES CORONA GENERATORS

  • Maximum uptime with automatic power adjustment during production fluctuations.
  • Enhanced operator safety through multi-level protections & interlocks.
  • Quick diagnosis with self-diagnostic tools & alarm systems.
  • Energy-efficient power delivery with programmable cut-off speeds.
  • Seamless integration with existing corona treaters and scalable for future needs.
pvnlogo4
CEcertifiedl
pvnlogo1
pvnlogo2
pvnlogo3

Corona
treatring
power supplies

Coronatreatringpowersupplies_updated
 
CGR-SIMPLEX
CGR-FLEX
CGR-PRO
CGR-PRO PLUS

Operating Features

Display LED-Membrane LED-Segmentd HMI-Touch  HMI-Touch  
Power Control POT-Based  POT-Based  On-Screen  On-Screen
Error/Fault Indicator            
Error/Fault Log           
Interlocks Status           

Discharge Modes

kW-Discharge       
Watt-Density Discharge         
Speed Proportional Control   (On Order)     

Control Mode

Standard Control            
External I/O Control        
External BUS          

Communication

MODBUS              
Industry 4.0        (On Order)   
IoT Dashboard              

Additional Features

Uniform Discharge Mode   (On Order)      
Cascading Generators        